Abstract
Purpose
To study the prevalence of posterior corneal astigmatism (PCA) and aberration in Chinese eyes before cataract surgery.
Methods
A cross-sectional study was conducted in Eye and ENT Hospital of Fudan University, Shanghai. In all, we enrolled 1976 eligible eyes of 1976 cataract patients. The astigmatism and aberrations of anterior and posterior cornea were measured by the rotating Scheimpflug System (Pentacam HR, Oculus). Cataract was diagnosed using slit-lamp examination.
Results
The mean age of patients was 61.82 ± 13.67 years old. Mean PCA was 0.28 ± 0.16 (range 0–1.0) D and 87.04% eyes had PCA values <0.5 D. WTR astigmatism predominated the anterior cornea astigmatism (43.1%), while ATR astigmatism predominated posterior (85.4%) and total corneal astigmatism (47.2%). We found a shift tendency of WTR to ATR with aging in anterior corneal astigmatism, while PCA remains ATR. A positive correlation between the magnitude of anterior and posterior corneal astigmatism (r2 = 0.089, P < 0.001) was found, especially in WTR anterior cornea astigmatism eyes (r2 = 0.298, P < 0.001). Compared with total corneal astigmatism, anterior corneal measurements overestimated WTR astigmatism by a mean of 0.24 ± 0.13 (D), and underestimated ATR astigmatism and oblique astigmatism in most eyes. Furthermore, anterior corneal aberrations measurements overestimated the total corneal aberration in most eyes.
Conclusions
About 12.96% of eyes had PCA ≥0.5 D. The posterior surface remained ATR astigmatism in most cases with aging. Neglecting the posterior cornea would result in overestimation in WTR anterior corneal eyes and underestimation in ATR and oblique anterior corneal eyes. Also, the posterior corneal aberration was also essential in clinics.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Kohnen T. Posterior corneal astigmatism. J Cataract Refract Surg. 2013;39:1795.
DelMonte DW, Kim T. Anatomy and physiology of the cornea. J Cataract Refract Surg. 2011;37:588–98.
Holland E, Lane S, Horn JD, Ernest P, Arleo R, Miller KM. The AcrySof Toric intraocular lens in subjects with cataracts and corneal astigmatism: a randomized, subject-masked, parallel-group, 1-year study. Ophthalmology. 2010;117:2104–11.
Waltz KL, Featherstone K, Tsai L, Trentacost D. Clinical outcomes of TECNIS toric intraocular lens implantation after cataract removal in patients with corneal astigmatism. Ophthalmology. 2015;122:39–47.
Ho JD, Tsai CY, Liou SW. Accuracy of corneal astigmatism estimation by neglecting the posterior corneal surface measurement. Am J Ophthalmol. 2009;147:788–95.
Koch DD, Ali SF, Weikert MP, Shirayama M, Jenkins R, Wang L. Contribution of posterior corneal astigmatism to total corneal astigmatism. J Cataract Refract Surg. 2012;38:2080–7.
Ho JD, Liou SW, Tsai RJ, Tsai CY. Effects of aging on anterior and posterior corneal astigmatism. Cornea. 2010;29:632–7.
Savini G, Versaci F, Vestri G, Ducoli P, Naeser K. Influence of posterior corneal astigmatism on total corneal astigmatism in eyes with moderate to high astigmatism. J Cataract Refract Surg. 2014;40:1645–53.
Cheng LS, Tsai CY, Tsai RJ, Liou SW, Ho JD. Estimation accuracy of surgically induced astigmatism on the cornea when neglecting the posterior corneal surface measurement. Acta Ophthalmol. 2011;89:417–22.
Zheng T, Chen Z, Lu Y. Influence factors of estimation errors for total corneal astigmatism using keratometric astigmatism in patients before cataract surgery. J Cataract Refract Surg. 2016;42:84–94.
Savini G, Naeser K. An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses. Invest Ophthalmol Vis Sci. 2015;56:827–35.
Miyake T, Shimizu K, Kamiya K. Distribution of posterior corneal astigmatism according to axis orientation of anterior corneal astigmatism. PLoS ONE. 2015;10:e117194.
Barkana Y, Gerber Y, Elbaz U, et al. Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry. J Cataract Refract Surg. 2005;31:1729–35.
Kim JS, Chung SH, Joo CK. Clinical application of a Scheimpflug system for lens density measurements in phacoemulsification. J Cataract Refract Surg. 2009;35:1204–9.
Lackner B, Schmidinger G, Skorpik C. Validity and repeatability of anterior chamber depth measurements with Pentacam and Orbscan. Optom Vis Sci. 2005;82:858–61.
Buehl W, Stojanac D, Sacu S, Drexler W, Findl O. Comparison of three methods of measuring corneal thickness and anterior chamber depth. Am J Ophthalmol. 2006;141:7–12.
Shankar H, Taranath D, Santhirathelagan CT, Pesudovs K. Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements. J Cataract Refract Surg. 2008;34:103–13.
Dunne MC, Royston JM, Barnes DA. Posterior corneal surface toricity and total corneal astigmatism. Optom Vis Sci. 1991;68:708–10.
Dunne MC, Royston JM, Barnes DA. Normal variations of the posterior corneal surface. Acta Ophthalmol. 1992;70:255–61.
Royston JM, Dunne MC, Barnes DA. Measurement of posterior corneal surface toricity. Optom Vis Sci. 1990;67:757–63.
Prisant O, Hoang-Xuan T, Proano C, Hernandez E, Awwad ST, Azar DT. Vector summation of anterior and posterior corneal topographical astigmatism. J Cataract Refract Surg. 2002;28:1636–43.
Modis LJ, Langenbucher A, Seitz B. Evaluation of normal corneas using the scanning-slit topography/pachymetry system. Cornea. 2004;23:689–94.
Dubbelman M, Sicam VA, Van der Heijde GL. The shape of the anterior and posterior surface of the aging human cornea. Vision Res. 2006;46:993–1001.
Naderan M, Rajabi MT, Zarrinbakhsh P. Distribution of the anterior and posterior corneal astigmatism in eyes with keratoconus. Am J Ophthalmol. 2016;167:79–87.
Ueno Y, Hiraoka T, Beheregaray S, Miyazaki M, Ito M, Oshika T. Age-related changes in anterior, posterior, and total corneal astigmatism. J Refract Surg. 2014;30:192–7.
Campbell CE. A new method for describing the aberrations of the eye using Zernike polynomials. Optom Vis Sci. 2003;80:79–83.
Acknowledgements
The study was supported by grants for Natural Science Foundation of China (NSFC 81300745, NSFC81670835, and NSFC81600719), Shanghai Science and Technology Commission (11231200602), New One Hundred People’s Plan of Shanghai Health Bureau (XBR2011056), and Visual Impairment and Reconstruction Key Laboratory of Shanghai (12DZ2260500).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Rights and permissions
About this article
Cite this article
Jiang, Y., Tang, Y., Jing, Q. et al. Distribution of posterior corneal astigmatism and aberration before cataract surgery in Chinese patients. Eye 32, 1831–1838 (2018). https://doi.org/10.1038/s41433-018-0186-0
Received:
Revised:
Accepted:
Published:
Version of record:
Issue date:
DOI: https://doi.org/10.1038/s41433-018-0186-0
This article is cited by
-
Analysis of differences between keratometric astigmatism and total corneal astigmatism measured by IOLMaster 700
International Ophthalmology (2025)
-
Analysis of corneal astigmatism and aberration in chinese congenital cataract and developmental cataract patients before cataract surgery
BMC Ophthalmology (2021)
-
Distribution and internal correlations of corneal astigmatism in cataract patients
Scientific Reports (2021)