Abstract
Objective
To assess the effect of reduced contrast sensitivity on three commonly used colour vision tests in order to establish key discrepancies that may be relevant for clinical practice.
Methods
A prospective non-interventional clinical study of colour vision testing using three commonly used devices: Ishihara and Hardy–Rand–Rittler (H-R-R) pseudoisocochromatic plate tests, and Farnsworth D-15 arrangement test performed under progressively reduced contrast sensitivity conditions achieved with a neutral density filter bar.
Results
The Pelli–Robson contrast sensitivity (PRCS) at which 5% of the population should first experience a 10% reduction in colour vision testing from baseline was calculated for each of the three colour vision devices: Farnsworth D-15 test: 1.81 log contrast sensitivity (CS), H-R-R test: 1.69 log CS, and Ishihara test: 1.34 log CS. Single factor repeated measures analyses, conducted separately at each contrast sensitivity level, revealed no difference between the colour vision testing devices at PRCS ≥1.80 log CS (P ≥ 0.367). However, in all PRCS ≤1.65 log CS, the differences were statistically significant (all P ≤ 0.004), demonstrating a significantly lower percentage of errors in the Ishihara test compared with both the Farnsworth D-15 (P < 0.023) and H-R-R (P < 0.035) tests.
Conclusions
At high contrast sensitivities, all colour vision tests function almost equally; however, at decreased levels of contrast sensitivity, H-R-R and Farnsworth D-15 are more greatly affected.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Almog Y, Nemet A. The correlation between visual acuity and color vision as an indicator of the cause of visual loss. Am J Ophthalmol. 2010;149:1000–4.
Huna-Baron R, Glovinsky Y, Habot-Wilner Z. Comparison between Hardy-Rand-Rittler 4th edition and Ishihara color plate tests for detection of dyschromatopsia in optic neuropathy. Graefes Arch Clin Exp Ophthalmol. 2013;251:585–9.
Zhao J, Dave SB, Wang J, Subramanian PS. Clinical color vision testing and correlation with visual function. Am J Ophthalmol. 2015;160:547–52 e541.
McCulley TJ, Golnik KC, Lam BL, Feuer WJ. The effect of decreased visual acuity on clinical color vision testing. Am J Ophthalmol. 2006;141:194–6.
Richman J, Spaeth GL, Wirostko B. Contrast sensitivity basics and a critique of currently available tests. J Cataract Refract Surg. 2013;39:1100–6.
Feigl B, Brown B, Lovie-Kitchin J, Swann P. Monitoring retinal function in early age-related maculopathy: visual performance after 1 year. Eye (Lond). 2005;19:1169–77.
Gupta L, Cvintal V, Delvadia R, Sun Y, Erdem E, Zangalli C, et al. SPARCS and Pelli-Robson contrast sensitivity testing in normal controls and patients with cataract. Eye (Lond). 2017;31:753–61.
Matti MI, Chu ER, Keane M, Pseudovs K, Chen CS. Comprison of Ishihara and Hardy-Rand-Rittler pseudoisochromatic plates in non-arteritic anterior ischaemic optic neuropathy. Neuro-Ophthalmol. 2011;35:181–6.
Trobe JD, Beck RW, Moke PS, Cleary PA. Contrast sensitivity and other vision tests in the optic neuritis treatment trial. Am J Ophthalmol. 1996;121:547–53.
Wyszecki G, Stiles WS. High-level trichromatic color matching and the pigment-bleaching hypothesis. Vision Res. 1980;20:23–37.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest:
The authors declare that they have no conflict of interest.
Additional information
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Lipsky, L., Qureshi, H.M., Friling, R. et al. The effect of reduced contrast sensitivity on colour vision testing. Eye 33, 1068–1072 (2019). https://doi.org/10.1038/s41433-019-0361-y
Received:
Revised:
Accepted:
Published:
Version of record:
Issue date:
DOI: https://doi.org/10.1038/s41433-019-0361-y


