Abstract
Purpose
The purpose of this study is to develop and assess the accuracy of a new intraocular lens (IOL) power calculation method based on machine learning techniques.
Methods
The following data were retrieved for 260 eyes of 260 patients undergoing cataract surgery: preoperative simulated keratometry, mean keratometry of posterior surface, axial length, anterior chamber depth, lens thickness, and white-to-white diameter; model and power of implanted IOL; and subjective refraction at 3 months post surgery. These data were used to train different machine learning models (k-Nearest Neighbor, Artificial Neural Networks, Support Vector Machine, Random Forest, etc). Implanted lens characteristics and biometric data were used as input to predict IOL power and refractive outcomes. For external validation, a dataset of 52 eyes was used. The accuracy of the trained models was compared with that of the power formulas Holladay 2, Haigis, Barrett Universal II, and Hill-RBF v2.0.
Results
The SD of the prediction error in order of lowest to highest was the new method (designated Karmona) (0.30), Haigis (0.36), Holladay 2 (0.38), Barrett Universal II (0.38), and Hill-RBF v2.0 (0.40). Using the Karmona method, 90.38% and 100% of eyes were within ±0.50 and ±1.00 D respectively.
Conclusions
The method proposed emerged as the most accurate to predict IOL power.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Melles RB, Holladay JT, Chang WJ. Accuracy of intraocular lens calculation formulas. Ophthalmology 2018;125:169–78.
Cooke DL, Cooke TL. Comparison of 9 intraocular lens power calculation formulas. J Cataract Refract Surg. 2016;42:1157–64.
Wang Q, Jiang W, Lin T, Zhu Y, Chen C, Lin H, et al. Accuracy of intraocular lens power calculation formulas in long eyes: a systematic review and meta-analysis. Clin Exp Ophthalmol. 2018;46:738–49.
Abulafia A, Barrett GD, Rotenberg M, Kleinmann G, Levy A, Reitblat O, et al. Intraocular lens power calculation for eyes with an axial length greater than 26.0 mm: comparison of formulas and methods. J Cataract Refract Surg. 2015;41:548–56.
Roberts TV, Hodge C, Sutton G, Lawless M. Comparison of Hill-radial basis function, Barrett Universal and current third generation formulas for the calculation of intraocular lens power during cataract surgery. Clin Exp Ophthalmol. 2018;46:240–6.
Gökce SE, Zeiter JH, Weikert MP, Koch DD, Hill W, Wang L. Intraocular lens power calculations in short eyes using 7 formulas. J Cataract Refract Surg. 2017;43:892–7.
Hill W. Hill-RBF calculator. Available at: http://rbfcalculator.com/online/index.html. Accessed 1 Jan 2018.
Reitblat O, Levy A, Kleinmann G, Lerman TT, Assia EI. Intraocular lens power calculation for eyes with high and low average keratometry readings: comparison between various formulas. J Cataract Refract Surg. 2017;43:1149–56.
Hoffer KJ, Aramberri J, Haigis W, Olsen T, Savini G, Shammas HJ, et al. Protocols for studies of intraocular lens formula accuracy. Am J Ophthalmol. 2015;160:403–5.
Koch DD, Hill W, Abulafia A, Wang L. Pursuing perfection in intraocular lens calculations: I. Logical approach for classifying IOL calculation formulas. J Cataract Refract Surg. 2017;43:717–8.
Kuhn M. Building predictive models in R using the caret package. J Stat Software. 2008;28:1–26.
Leo B. Stacked regressions. Mach Learn. 1996;24:49–64.
Aristodemou P, Cartwright NEK, Sparrow JM, Johnston RL. Statistical analysis for studies of intraocular lens formula accuracy. Am J Ophthalmol. 2015;160:1085–6.
Benavoli A, Corani G, Mangili F. Should we really use post-hoc tests based on mean-ranks? J Mach Learn Res. 2016;17:1–10.
Kane JX, Van Heerden A, Atik A, Petsoglou C. Accuracy of 3 new methods for intraocular lens power selection. J Cataract Refract Surg. 2017;43:333–9.
Shiny from RStudio. Available at: https://shiny.rstudio.com/. Accessed 4 May 2019.
Acknowledgements
The contribution of Ana Burton as a reviewer has been supported by Department of Medicine of the School of Biomedical Sciences and Health (Universidad Europea de Madrid).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Carmona González, D., Palomino Bautista, C. Accuracy of a new intraocular lens power calculation method based on artificial intelligence. Eye 35, 517–522 (2021). https://doi.org/10.1038/s41433-020-0883-3
Received:
Accepted:
Published:
Version of record:
Issue date:
DOI: https://doi.org/10.1038/s41433-020-0883-3
This article is cited by
-
Comparative evaluation of traditional and AI-based intraocular lens power calculation formulas in highly myopic eyes
BMC Ophthalmology (2025)
-
Adopting machine learning to predict nomogram for small incision lenticule extraction (SMILE)
International Ophthalmology (2025)
-
Advances in the management of uveitic cataract: current strategies and emerging perspectives
International Ophthalmology (2025)
-
The effect of corneal power on the accuracy of 14 IOL power formulas
BMC Ophthalmology (2024)
-
Comparison of the formula accuracy for calculating multifocal intraocular lens power: a single center retrospective study in Korean patients
Scientific Reports (2024)