Table 4 Chilldown efficiencies and mass flow rates for the six flight cases.
Reduced-G | Ground-G | ||||
|---|---|---|---|---|---|
Case | Teflon coated | Bare SS304 | Mass flow rate, kg/s | Teflon coated | SS304 |
1 (micro-g) 80 psig, continuous flow | 18.54% | 13.38% | 0.0253 | 23.19% | 19.54% |
2 (micro-g) 80 psig 40% DC, 1 s Period | 28.50% | 21.26% | 0.0350 | 28.49% | 21.74% |
3 (micro-g) 80 psig 70% DC, 1 s Period | 23.48% | 13.65% | 0.0239 | 21.17% | 17.78% |
4 (micro-g) 60 psig, continuous flow | 28.40% | 17.83% | 0.0100 | 24.50% | 18.58% |
5 (micro-g) 90 psig, continuous flow | 16.87%* | 12.96%* | 0.0264* | 17.26% | 14.32% |
6 (micro-g) 90 psig 50% DC, 1 s Period | 23.88%* | 18.63%* | 0.0255* | 20.52% | 16.76% |