Table 1 Summary of experiments.

From: Aerosol jet printed capacitive strain gauge for soft structural materials

Device

Device type

Test Type

Electrode orientation relative to strain direction

C0 or R0

Figure #

a

Capacitive

Dynamic, static

Perpendicular

46.436 ± 0.002 pF

4a, 4c

b

Capacitive

Dynamic, static

Perpendicular

15.22 ± 0.03 nF

4a, 4c

c

Capacitive

Dynamic, static

Perpendicular

9.25 ± 0.04 nF

4a, 4c

d

Capacitive

Dynamic, static

Parallel

42.51 ± 0.02 pF

4b, 4d

e

Capacitive

Dynamic, static

Parallel

43.61 ± 0.02 pF

4b, 4d

f

Capacitive

Cyclic

Perpendicular

11.07 ± 0.03 nF

4e

g

Capacitive

Cyclic

Perpendicular

43.57 ± 0.04 pF

4e

h

Capacitive

bending

N/A

6.22 ± 0.02 pF

4f

HBM_1

Resistive

Dynamic, Static

Perpendicular

353 Ω

5a, 5c

HBM_2

Resistive

Dynamic, Static

Perpendicular

353 Ω

5a, 5c

HBM_3

Resistive

Cyclic

Perpendicular

350 Ω

5c

HBM_4

Resistive

Cyclic

Perpendicular

350 Ω

5c