Table. 1 Measured thermal conductivity of samples.
Sample number | d (μm) | L (μm) | k (W m−1K−1) |
|---|---|---|---|
S1 | 0.95 ± 0.07 | 5.99 ± 0.02 | 0.28 (0.286 ± 0.018) |
S2 | 1.23 ± 0.03 | 10.04 ± 0.01 | 0.28 (0.280 ± 0.005) |
S3 | 1.12 ± 0.09 | 4.52 ± 0.02 | 0.28 (0.278 ± 0.002) |
Sample number | d (μm) | L (μm) | k (W m−1K−1) |
|---|---|---|---|
S1 | 0.95 ± 0.07 | 5.99 ± 0.02 | 0.28 (0.286 ± 0.018) |
S2 | 1.23 ± 0.03 | 10.04 ± 0.01 | 0.28 (0.280 ± 0.005) |
S3 | 1.12 ± 0.09 | 4.52 ± 0.02 | 0.28 (0.278 ± 0.002) |