Table 2 OECTs for dopamine sensing

From: Biomolecule sensors based on organic electrochemical transistors

Gate

Channel material

Electrolyte

Current sensitivity

Detection limit

Detection range

Ref.

Au/aptamer

PEDOT:PSS

Tris buffer

-

0.5 fΜ

5 fM–1 nΜ

88

CSF/rGO/Nafion

PEDOT:PSS

PBS

-

1 nM

1 nM–30 μM

6

NOCC-O

PEDOT:PSS

PBS

-

0.17 μM

1 μM–0.3 mM

87

Fiber/NFs/PPy

PPy

PBS

47.28 NCR/decade

-

1 nM–1 μM

96

Pt

PEDOT:PSS

PBS

-

1 nM

1 nM–1 μM

99

Au

PEDOT:PSS

PBS

-

-

0–10 μM

95

Pt

PEGDA:PEDOT

PBS

-

-

100 nM–5 mM

98

PEDOT:PSS

PEDOT:PSS

PBS

190 ± 20 pA/decade

138 ± 6 pA/decade

1 pM

1 pM–160 pM

2 nM–700 nM

97

Nafion/graphene/Pt

PEDOT:PSS

PBS

-

5 nM

5 nM–1 μM

86

Ag/AgCl

AuNPs/PEDOT:PSS

PBS

-

37 nM

50 nM–100 μM

90

Pt

PEDOT:PSS

PBS

-

5 nM

50 nM–3 μM

83

Carbon fiber

PEDOT:PSS

PBS

-

5 pM

-

7

o-MIP/Pt

PEDOT:PSS

PBS

-

0.35 μM

0.4 μM–10 μM

89

Pt

PEDOT:PSS

PBS

-

1 nM

0.1 μM–10 μM

5

PEDOT:PSS

PEDOT:PSS

PBS

-

6 μM

0.005 mM–0.1 mM

93

Ag/AgCl

PEDOT:PSS/DMSO

/GOPS

PBS

-

61 nM

1 nM–100 μM

91

Pt

PEDOT:PSS/CTAB

PBS

-

-

1–300 μM

92