Table 2 Summary of rr determination for SON68 glass altered at 90 °C.

From: Aqueous alteration of silicate glass: state of knowledge and perspectives

Onset solution

Mode

S/V (m−1)

pH90°C

Δt or t (days)

Log(rr)

Ref.

DIW

S

1200

9.7

365

−3.4

194

DIW

S

1200

9.7

1825

−3.3

DIW

S

8000

9.2

365

−3.5

DIW

S

8000

9.1

1825

−4

DIW

S

200,000

9.2

365

−4

DIW

S

200,000

9.4

1825

−3.5

DIW

S

8000

9.3

4015

−3.8

196

C(Si) = 100 mg.L−1, pH 9

S

8000

9.1

365

−3.7

194

C(Si) = 250 mg.L−1, pH 9.3

CF

14,000

9.3(c)

200

−3.3

199

DIW

S

1200

8.9(c)

500–4500

−3.9

98

DIW + KOH

S

1500

7, 8, 9.5,10, 10.5

594

[−4; −3.5]

206

Cox groundwater

S

1000

6.1

273–673

−2.7

92

  1. DIW stands for deionized water. Cox stands for Callovo-Oxfordian claystone. S, CF stand for static, or continuous flow, respectively. The pH is given at 90 °C ((c) = calculated or estimated from data obtained at room temperature) and corresponds to a mean value at the time when rr was calculated. rr is given in g.m−2.d−1. Uncertainty on rr is estimated at 0.2 log units.