Fig. 14: Schematic diagram of resistance mechanism of Cu-bearing steel to B. cereus and SCC.

The steel without Cu precipitated phase is not only corroded by microorganisms, but also produces cracking, while the steel containing Cu precipitated phase causes bacterial death and disperses hydrogen accumulation.