Table 2 Technique details of the studies included in the meta-analysis.

From: Transcriptional signatures of the whole-brain voxel-wise resting-state functional network centrality alterations in schizophrenia

Study

Scanner

Sequence

GS removed

FWHM (mm)

TR (ms)

TE (ms)

ST (mm)

Correlation coefficient

Binary/weighted FNC

Threshold

Number of coordinates

Chen et al.52 (2015)a

GE

EPI

Yes

6

2000

30

4

0.25

Weighted

P < 0.01 (corrected)

3

Chen et al.52 (2015)a

GE

EPI

Yes

6

2000

30

4

0.25

Weighted

P < 0.01 (corrected)

3

Chen et al.53 (2022)b

GE

GRE-SS-EPI

No

6

2000

30

4

0.2

Weighted

P < 0.05 (corrected)

4

Chen et al.53 (2022)b

GE

GRE-SS-EPI

No

6

2000

30

4

0.2

Weighted

P < 0.05 (corrected)

7

Chen et al.54 (2018)

Siemens

EPI

No

4

2000

30

4

0.2

Binary

P < 0.05 (corrected)

1

Chen et al.11 (2019)

Siemens

EPI

No

6

2000

30

4

0.2

Binary

P < 0.05 (corrected)

6

Chen et al.55 (2019)c

GE

Gradient-recalled EPI

Yes

4

2000

35

3.6

0.25

Weighted

P < 0.05 (corrected)

7

Chen et al.55 (2019)c

GE

Gradient-recalled EPI

Yes

4

2000

35

3.6

0.25

Weighted

P < 0.05 (corrected)

4

Ding et al.56 (2019)

Siemens

GRE-EPI

No

4

2000

30

4

NA

Weighted

P < 0.05 (corrected)

7

Guo et al.57 (2015)

Siemens

GRE-EPI

No

8

2000

30

4

NA

Weighted

P < 0.001 (corrected)

3

Guo et al.58 (2017)

Philips

GRE-EPI

No

4

2000

30

5

NA

Weighted

P < 0.001 (corrected)

6

Kang et al.59 (2020)

Siemens

EPI

No

6

3000

30

3

0.6

Binary

P < 0.05 (corrected)

5

Li et al.16 (2020)

Siemens

GRE-EPI

No

NA

2000

30

4

NA

Weighted

P < 0.05 (corrected)

4

Lei et al.60 (2015)

GE

EPI

Yes

6

2000

30

5

0.25

Binary

P < 0.05 (corrected)

2

Miao et al.61 (2020)d

GE

NA

No

4

2000

40

5

0.2

Weighted

P < 0.05 (corrected)

7

Miao et al.61 (2020)d

GE

NA

No

4

2000

40

5

0.2

Weighted

P < 0.05 (corrected)

4

Palaniyappan et al.15 (2014)

Philips

GRE-EPI

Yes

8

2500

25/53

4

0.25

Binary

P < 0.05 (corrected)

13

Skåtun et al.12 (2016)

GE

GRE-EPI

No

6

2638

30

3

NA

Binary

P < 0.05 (corrected)

12

Wang et al.62 (2018)

Siemens

EPI

No

8

3000

30

3

0.6

Binary

P < 0.05 (corrected)

2

Wang et al.63 (2017)

Siemens

EPI

No

6

2000

30

4

FWE correction

Binary

P < 0.05 (corrected)

7

Yang et al.64 (2020)

Phillips

EPI

No

6

2000

30

4

0.3

Binary

P < 0.005 (uncorrected)

2

Yu et al.14 (2021)

Siemens

GRE-EPI

No

6

2000

30

4

0.25

Binary

P < 0.05 (corrected)

4

Zhao et al.65 (2022)

Siemens

EPI

No

4

2000

30

NA

NA

Weighted

P < 0.05 (corrected)

5

Zhou et al.10 (2022)

Siemens

GRE-EPI

No

8

2000

30

4

0.25

Weighted

P < 0.05 (corrected)

3

Zhuo et al.13 (2017)

GE

GRE-SS-EPI

No

6

2000

45

4

0.6

Binary

P < 0.05 (corrected)

13

  1. EPI echo planar imaging, FNC functional network centrality, FWE family-wise error, FWHM full-width at half-maximum, GE General Electric, GRE gradient echo, GS global signal, NA not available, SS single shot, ST slice thickness, TE time of echo, TR time of repetition.
  2. a–dThe four studies divided patients into two datasets based on different symptoms.