Table 2 The conversion from Wa or Qa to a common platform of QSPE.
CCGT power plant with MED for desalination | Actual work or heat input (MW) | Standard primary energy at common energy platform (MW) | Specific standard primary consumption at the common energy platform, computed with an average value. (QSPE/m3) | |
|---|---|---|---|---|
Gas and steam turbines (electricity, MW) | Wa = 1094.37 (electricity) | QSPE = 1896.30 | SWRO 3.5 to 5.5 kWhelec/m3 | QSPE = 4.5(1.733) = 7.80 kWhSPE/m3 |
CFelec = 1896.30/1094.37 = 1.733 | ||||
MED | 0.125 | MED 40 to 80 kWhth/m3 and 0.8 to 1.2 kWhelec/m3 | QSPE = 60(0.125) + 1.0(1.733)  = 9.23 kWhSPE/m3 | |