Extended Data Fig. 1: The error in the direction of the reconstructed magnetization vector field(Δθm) for different laminography tilt angles is determined by numerical simulations of magnetic laminography. | Nature Nanotechnology

Extended Data Fig. 1: The error in the direction of the reconstructed magnetization vector field(Δθm) for different laminography tilt angles is determined by numerical simulations of magnetic laminography.

From: Time-resolved imaging of three-dimensional nanoscale magnetization dynamics

Extended Data Fig. 1

The simulations show that there exists a range of angles (40°–80°) for which the 3D structure can be reconstructed with a high degree of accuracy. The accuracy of the reconstruction is determined by calculating the RMS error of the direction of the reconstructed magnetization with respect to the original structure (Δθm). The tilt angle used in the experiment presented in this manuscript is 61°, which lies comfortably within this range and is indicated with an arrow.