Extended Data Fig. 5: Electrochemical performance data of solid state cell components.
From: Healable and conductive sulfur iodide for solid-state Li–S batteries

The cycling stability and capacity of a LPS/VGCF cathode at 100 °C (a) and 25 °C (c). The corresponding voltage profiles at 100 °C (b) and at 25 °C (d). Capacity contribution of LPS is very limited and the cycling stability of LPS is very poor either at 100 °C or 25 °C with low coulombic efficiencies. The long-term cycling stability of Li/SP/LPSCl/SP/Li symmetric cells at 100 °C (e) and 25 °C (f) at a current density of 0.3 mA cm−2.