Table 1 Cryo-EM data collection, refinement and validation statistics

From: CENP-N promotes the compaction of centromeric chromatin

 

AN mono (α sat) (EMDB-26330) (PDB 7U46)

AN stack (α sat) (EMDB-26331) (PDB 7U47)

AN stack (601) (EMDB-26332) (PDB 7U4D)

AN 12-mer (601) (EMDB-26333)

Data collection and processing

Magnification

29,000

29,000

22,500

Voltage (kV)

300

300

300

Electron exposure (e2)

70

80

100

Defocus range (μm)

0.8–2.0

1.0–2.5

1.3–2.5

Pixel size (Å)

0.8211

1.02

0.655

Symmetry imposed

C1

C1

C1

Initial particle images (no.)

555,254

292,321

13,356

Final particle images (no.)

314,239

88,530

174,936

9,305

Map resolution (Å)

2.68

3.54

5.30

12.70

 FSC threshold

0.143

0.143

0.143

0.143

Map resolution range (Å)

2.5–4.5

3.5–10

5.0–12.0

12.5–28.0

Refinement

Initial model used (PDB code)

1KX5, 6C0W

6C0W

 

Model resolution (Å)

2.7

3.8a

5.9a

 

 FSC threshold

0.143

0.143

0.143

 

Model resolution range (Å)

2.5–4.5

3.5–9.4

5.9–11.9

 

Map sharpening B factor (Å2)

Model composition

 Non-hydrogen atoms

13,362

26,724

262,444

 

 Protein residues

925

1,850

1,850

 

 Nucleotide

290

580

556

 

 Ligands

0

0

0

 

B factors (Å2)

 Protein

77.09

77.09

65.96

 

 Nucleotide

108.23

108.23

121.56

 

 Ligand

n/a

n/a

n/a

 

R.m.s. deviations

 Bond lengths (Å)

0.011

0.011

0.006

 

 Bond angles (°)

0.781

0.913

0.972

 

Validation

 MolProbity score

1.38

1.4

1.58

 

 Clashscore

4.10

4.41

4.65

 

 Poor rotamers (%)

0.00

0.00

0.00

 

Ramachandran plot

 Favored (%)

96.91

96.91

95.08

 

 Allowed (%)

3.09

3.09

4.92

 

 Disallowed (%)

0.00

0.00

0.00

 
  1. aDue to severe orientation issues, the reported resolution is not an accurate reflection of the map quality.