Table 4 Description of metadata for key values obtained via test procedures 1 and 2 according to UL 1974.

From: Charge and discharge profiles of repurposed LiFePO4 batteries based on the UL 1974 standard

Data

Unit

Description

As per UL 1974

SN

 

Serial number of the cell

N/A

\(OC{V}_{ini}\)

V

Initial OCV

19.2 Re

\(Ca{p}_{D}\)

Ah

Discharge ampere hour capacity at \({C}_{R}=0.5{{\rm{h}}}^{-1}\)

19.4 Re

\(Ca{p}_{C}\)

Ah

Discharge ampere hour capacity at \({C}_{R}=0.5{{\rm{h}}}^{-1}\)

19.4 Ex

\(X\) of \(Ca{p}_{RX}\)

 

Grouped by measured discharge ampere hour capacity \(Ca{p}_{RX}\)

19.4 Ex

\({R}_{85}\)

\(\Omega \)

DCIR obtained by two-tier DC load method at SOC = 85%

19.5 Re

\({V}_{85,1}\)

V

Measured voltage \({V}_{1}\) under the first tier at SOC = 85%

19.5 Re

\({I}_{85,1}\)

A

Measured current \({I}_{1}\) under the first tier at SOC = 85%

19.5 Re

\({V}_{85,2}\)

V

Measured voltage \({V}_{2}\) under the second tier at SOC = 85%

19.5 Re

\({I}_{85,2}\)

A

Measured current \({I}_{2}\) under the second tier at SOC = 85%

19.5 Re

\({R}_{20}\)

\(\Omega \)

DCIR obtained by two-tier DC load method at SOC = 20%

19.5 Re

\({V}_{20,1}\)

V

Measured voltage \({V}_{1}\) under the first tier at SOC = 20%

19.5 Re

\({I}_{20,1}\)

A

Measured current \({I}_{1}\) under the first tier at SOC = 20%

19.5 Re

\({V}_{20,2}\)

V

Measured voltage \({V}_{2}\) under the second tier at SOC = 20%

19.5 Re

\({I}_{20,2}\)

A

Measured current \({I}_{2}\) under the second tier at SOC = 20%

19.5 Re

\(Ca{p}_{C1}\)

Ah

Charge ampere hour capacity at \({C}_{R}=0.5{{\rm{h}}}^{-1}\)

19.7 Ex

\(Ca{p}_{DN}\)

Ah

Discharge ampere hour capacity under normal loading conditions (\({C}_{R}=0.5{{\rm{h}}}^{-1}\))

19.7 Re

\(Ca{p}_{C2}\)

Ah

Charge ampere hour capacity at \({C}_{R}=0.5{{\rm{h}}}^{-1}\)

19.7 Ex

\(Ca{p}_{DM}\)

Ah

Discharge ampere hour capacity under maximum loading conditions (\({C}_{R}=1{{\rm{h}}}^{-1}\))

19.7 Re

\(Ca{p}_{C3}\)

Ah

Charge ampere hour capacity at \({C}_{R}=0.5{{\rm{h}}}^{-1}\)

19.7 Ex

\(OC{V}_{5m}\)

V

Measured OCV at 5 minutes after full charge

19.8 Re

\(OC{V}_{1h}\)

V

Measured OCV at 1 hour after full charge

19.8 Re

\(OC{V}_{24h}\)

V

Measured OCV at 24 hours after full charge

19.8 Re

  1. The word “Re” (“Ex”) in the “As per UL 1974” column indicates that the key value is required by UL 1974 (extended data of UL 1974).