Table 1 Description of sample delivery conditions and corresponding run number.
From: A multi-million image Serial Femtosecond Crystallography dataset collected at the European XFEL
Run number | Duration (mins) | Flow rate (μL/min) | He pressure (psi) | He flow rate (mg/min) | Jet velocity (m/s) | Frame count | Indexed count | Indexing rate (%) |
|---|---|---|---|---|---|---|---|---|
79 | 10.1 | 30 | 450 | 34.0 | 50.8 | 2,129,547 | 47,129 | 2.21 |
80 | 12.1 | 30 | 450 | 34.0 | 50.8 | 2,564,884 | 20,156 | 0.79 |
84 | 10.0 | 80 | 400 | 26.0 | 37.4 | 2,116,224 | 20,479 | 0.97 |
85 | 10.0 | 80 | 400 | 26.0 | 37.4 | 2,116,224 | 30,401 | 1.44 |
95 | 10.0 | 60 | 450 | 34.0 | 44.0 | 2,113,760 | 31,697 | 1.5 |
96 | 10.0 | 60 | 450 | 34.0 | 44.0 | 2,113,760 | 40,239 | 1.9 |
98 | 10.0 | 60 | 300 | 14.0 | 31.2 | 2,115,520 | 40,802 | 1.93 |
99 | 10.2 | 60 | 300 | 14.0 | 31.2 | 2,154,241 | 74,437 | 3.46 |