Table 7 Sensor history for monitoring station P2 (1541 m), describing sensor replacements and upgrades from 2017 to 2022.

From: Six years of high-resolution climatic data collected along an elevation gradient in the Italian Alps

Station P2 (1541 m)

Measured variable

Sensor model/setup

Sensor height [m]

Period of operation

Start

End

Temperature, air - Humidity, relative

HC2S3

2.00

2016-06-26

2018-11-21

HC2S3

2.00

2018-11-21

2019-08-22

HMP155A

2.00

2019-08-22

2019-10-08

HMP155A

2.00

2019-10-08

ongoing

Wind speed - Wind direction

Wind Sentry Set 03002

2.00

2014-04-09

2017-06-01

Windsonic4

2.00

2017-06-01

ongoing

Precipitation

Pluvio2 + wind shield (ex B2 station)

1.50

2019-07-09

ongoing

Soil water content, volumetric - Temperature, soil

CS655*

−0.02

2014-06-16

ongoing

CS655*

−0.05

2014-04-09

ongoing

CS655*

−0.20

2014-04-09

ongoing

Soil water potential

MPS-6

−0.05

2019-03-20

ongoing

MPS-6

−0.20

2019-03-20

ongoing

  1. * Sensor installed in the area “Plot A” of the monitoring station P2.