Table 2 Folders/files info, and process overview.
Folder | Vicon (.c3d) | V3D (.cmz) | Exported spreadsheets (.csv) | MATLAB – raw (.mat) | MATLAB – secondary (.mat) | MATLAB – filtered (.mat) | MATLAB – segmented (.mat) | MATLAB – segmented (.csv) | Video | |
|---|---|---|---|---|---|---|---|---|---|---|
Trials represented in folder | Static (pose) trial | Yes | Yes | No | No | No | No | No | No | No |
Functional (range of motion) trial | Yes | No | No | No | No | No | No | No | No | |
Dynamic (sit-to-stand) trial included | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
Corrections | EMGs identified by muscle name or electrode number | Electrode number | Electrode number | Electrode number | Muscle | Muscle | Muscle | Muscle | Muscle | |
EMG delay corrected (TF01 only) | No, delayed | No, delayed | No, delayed | No, delayed | Yes | Yes | Yes | Yes | ||
Subject info: height, weight, prosthesis side, intact side, etc | No | No | No | No | No | No | Yes | Yes | ||
Subject anthropometrics | No | Yes, in Subject Data/Metrics | Yes (in separate file) | No | No | No | No | No | ||
Trajectories (200 Hz) | Yes | Yes | Yes (in separate file) | No | No | No | No | No | ||
Analog devices (2000 Hz) | Yes | Yes | Yes (in separate file) | No | No | No | No | No | ||
Variables included | Kinematic and kinetic variables (200 Hz) | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
Combined Force Structure - var name, sampling rate | FS1_1, 2000 Hz | FS1_1, 2000 Hz | COP_ combined, 2000 Hz | COP_ combined, 200 Hz | COP_ combined, 200 Hz | COP_ combined, 200 Hz | COP_ combined, 200 Hz | |||
Raw EMG signals included (2000 Hz), unit | Yes [V] | Yes [V] | Yes [V] | Yes [V] | Yes [V] | Yes [V] | Yes [μV] | Yes [μV] | ||
EMG envelopes (200 Hz), unit | No | No | No | No | No | Yes [V] | Yes [μV] | Yes [μV] | ||
Segment endpoint positions (200 Hz) | No | No | Yes (in separate file) | No | No | No | No | No | ||
“Shape” of each variable/ signal | n = frames (n varies with frame rate, see previous section). N = number of good segmented “Reps” | 1 × n | 1 × n | 1 × n | 1 × n | 1 × n | 1 × n | 1001 × N | 1001 × N | |
Signal types filtered | Trajectories filtered | No | Yes | Yes | ||||||
Analog devices filtered | No | Yes | Yes | |||||||
Kinematic, kinetic variables filtered | No | No | No | No | Yes | Yes | Yes | |||
Removing bad reps (dynamic only). Note: see Table 3 | Trials cropped | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Reps with stumbles removed | No | No | No | No | No | No | Yes | Yes | No | |
Torque, power, COP replaced with NaN in reps with hands | No | No | No | No | No | No | Yes | Yes | ||
EMGs replaced with NaN in reps with movement artifact | No | No | No | No | No | No | Yes | Yes |