Table 9 Flow conditions for numerical simulations of turbine cascade.

From: High-Reynolds-Number Turbulence Database: AeroFlowData

Case

Flow conditions

T106A

Rec = 60000, Inlet P0,∞ = 722.9 Pa, Inlet T = 298.15 K, Outlet P = 645.70 Pa, α = 45.5°

T106C

Rec = 80000, Inlet P0,∞ = 669.3 Pa, Inlet T = 298.15 K, Outlet P = 503.87 Pa, α = 32.7°

VKI LS89

Rec = 1.13 × 106, Inlet P0,∞ = 184,900 Pa, Inlet T0,∞ = 409.20 K, Outlet P = 182,000 Pa, α = 0°

  1. T is the static temperature, and P is the static pressure.