Table 1 Overview of the datasets.
From: Thermal reaction of the subsurface on the operation of a geothermal planar trench collector
Description | Unit | Dataset 118 | Dataset 220 | Dataset 321 | Dataset 422 |
|---|---|---|---|---|---|
Date of the dataset | DD.MM.YYYY | 28.04.2022-03.05.2022 | 28.02.2023-06.03.2023 | 06.04.2023-13.04.2023 | 02.05.2024-12.05.2024 |
Heat injection/extraction rate | kW | 0.88 ± 0.03407 | 1.51 ± 0.03569 | 1.54 ± 0.03577 | −0.7 ± 0.01895 |
Volume flow | m3/h | 1.00 ± 0.00739 | 0.88 ± 0.00725 | 0.88 ± 0.00725 | 0.35 ± 0.00673 |