Table 1 Mean pre and post sonication CBF and PS values obtained by DCE NIRS and CT as well as individual PS values measured at each of the four sonication powers.
From: Quantification of blood-brain barrier permeability by dynamic contrast-enhanced NIRS
Pre sonication | Post Sonication | |||||||
|---|---|---|---|---|---|---|---|---|
\(\overline{{\bf{CBF}}}\) (ml/100 g/min) | \(\overline{{\bf{PS}}}\) (ml/100 g/min) | \(\overline{{\bf{CBF}}}\) (ml/100 g/min) | PS (ml/100 g/min) | |||||
0.5 W | 1 W | 1.5 W | 2 W | |||||
ICG | DCE NIRS | 85.3 ± 22.4 | 0.06 ± 0.13 | 72.1 ± 18.5 | 0.41 | 1.09 | 1.63 | 2.93 |
CT | 70.3 ± 0.63 | 1.06 ± 0.24 | 55.8 ± 2.17 | 3.96 | 6.15 | 11.20 | 14.56 | |
IRDye | DCE NIRS | 71.8 ± 6.6 | 1.94 ± 1.36 | 58.8 ± 5.8 | 3.19 | 4.89 | 11.27 | 15.15 |
CT | 74.5 ± 5.83 | 1.08 ± 0.32 | 65.7 ± 26.5 | 3.64 | 7.25 | 9.98 | 16.97 | |