Table 1 Extracted parameters from application of phenomenological model to TID studies.

From: Phenomenological Model for Defect Interactions in Irradiated Functional Materials

 

Columnar

Equiaxed

φ N  × 103

k

φ N  × 103

k

εr

19

0.48

26

0.79

d33,f, remanent

185

0.66

142

0.77

d33,f, saturation

7

0.60

1

0.62

  1. Shown are dielectric permittivity and effective longitudinal piezoelectric response in gamma-irradiated PZT thin films. Data is extracted by fitting Equation (8) to percent change of given functional response measurement vs. radiation dose. Note that values of φ N are multiplied by three orders of magnitude to make interpretation more manageable.