Table 3 Refractive outcomes of Haigis and SRK/T formulas in patients with different axial lengths in the two groups.

From: Sustained accuracy improvement in intraocular lens power calculation with the application of quality control circle

Group

Without QCC group

QCC group

P value

ME

MAE

ME

MAE

ME

MAE

Normal AL

 Haigis

−0.09 ± 0.60

0.48 ± 0.38

−0.08 ± 0.44

0.31 ± 0.32

0.482

<0.001

 SRK/T

−0.15 ± 0.59

0.49 ± 0.36

−0.02 ± 0.48

0.35 ± 0.33

0.064

<0.001

Long AL

 Haigis

−0.69 ± 0.99

0.86 ± 0.83

−0.75 ± 0.75

0.78 ± 0.73

0.5414

0.9211

 SRK/T

−0.55 ± 1.03

0.80 ± 0.84

−0.61 ± 0.85

0.71 ± 0.78

0.6153

0.5803

PhacoOptics

−0.09 ± 0.69

0.45 ± 0.52

<0.001*

0.0012*

Total

 Haigis

−0.25 ± 0.77

0.58 ± 0.56

−0.31 ± 0.65

0.47 ± 0.54

0.6449

0.0058

 SRK/T

−0.26 ± 0.75

0.57 ± 0.54

−0.22 ± 0.69

0.47 ± 0.55

0.5052

0.0081

  1. QCC = Quality control circle, AL = Axial length, ME = Mean prediction error, MAE = Mean absolute prediction error. *The P value comes from comparing the results of PhacoOptics software with those of the Haigis and SRK/T formulas after the QCC activity.