Table 4 FWHM of different slice thicknesses measured by the nMAG gel dosimeter and Gafchromic film at 120 kVp.

From: Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography

FWHM (mm)

2 mm

5 mm

10 mm

14.4 mm

38.4 mm

Center

 Film

2.92

5.76

11.93

31.75

71.38

 nMAG gel

2.54

5.46

10.66

19.81

48.02

 Difference

13.0%

5.2%

10.6%

37.6%

32.7%

Periphery

 Film

2.57

5.28

10.06

18.39

47.48

 nMAG gel

2.36

4.63

9.65

17.81

41.86

 Difference

8.2%

12.3%

4.1%

3.2%

11.8%