Table 1 Percentage of temporal delay and attenuation of transmitted ramps with rise times of 100 and 200 ps. Electric field statistics in DMEM solution in the frequency domain.
From: A wide-band bio-chip for real-time optical detection of bioelectromagnetic interactions with cells
Time domain analysis: temporal delays & attenuation | ||||
|---|---|---|---|---|
% rise time increase | % attenuation | |||
200 ps | 100 ps | 200 ps | 100 ps | |
Without reservoir (air) | 27 | 66 | 15 | 14 |
Empty reservoir | 27 | 93 | 16 | 15 |
Reservoir non conductive | 30 | 111 | 15 | 16 |
Drop of H2O | 58 | 190 | 30 | 34 |
Reservoir conductive | 38 | 112 | 20 | 21 |
DMEM drop | 72 | 202 | 15 | 14 |
Frequency domain analysis: E field statistics | ||||
Frequency (MHz) | % CV of ROI solution height 25 µm | % CV of ROI solution height 10 µm | ||
100 | 28 | 11.2 | ||
200 | 26.4 | 10.6 | ||
800 | 27.8 | 11.12 | ||
1000 | 25.3 | 10.12 | ||
1600 | 23 | 9.2 | ||
3000 | 25.5 | 10.2 | ||