Table 1 The best-fit parameters of the modified second-order Avrami equation that was fitted to the pit density data shown in Fig. 4.

From: Direct observation of pitting corrosion evolutions on carbon steel surfaces at the nano-to-micro- scales

 

Parameters

a* (/h2)

b** (−)

R2

rmax§(/h)

tind (h)

tprop (h)

Deionized water

0.043

923.32

1.00

164.24

2.53

7.96

100 mM NaCl

0.670

899.60

0.99

631.65

0.64

2.02

  1. *,**Fitting parameters.
  2. §Maximum rate of increase in the pit density.
  3. Time at the end of induction period.
  4. Time at the end of propagation period.