Table 1 I–V characteristics measured under a two-stage CPV optical system.
Voc (V) | Jsc (mA) | FF | Power (mW) | Concentration ratio (X) | Enhancements (%) | |
|---|---|---|---|---|---|---|
Representative single-point measurement | Averaged from over 4 measurements | |||||
Bare ball & primary | 3.14 | 11.33 | 0.836 | 29.7 | 227.9 ± 1.3 | — |
Etched ball & bare primary | 3.14 | 12.07 | 0.840 | 31.8 | 242.0 ± 0.5 | 6.2 ± 0.7 |