Table 2 Optimization of Tap and Underground Water Slightly Acidic Electrolyzed Water production system by combining 1.0–3.0 M KCl with 4% HCl and its physicochemical properties.
Water source | Input | Output | |||||
|---|---|---|---|---|---|---|---|
Electrolyte concentration | Electrolyte Flow rate (mL/min) | Amperage (A) | Voltage (V) | pH | ACC (ppm) | ORP (mV) | |
Tap Water | 4% HCl (control) | 4.00 | 12.0 | 3.0 | 3.21 | 42.5 | 1060/1074 |
3.00 | 3.4 | 3.31 | 32 | 1018/1039 | |||
2.00 | 3.6 | 3.64 | 31 | 848/974 | |||
1.00 | 3.8 | 4.31 | 14.5 | 819/922 | |||
4% HCl + 1.0 M KCl | 4.00 | 12.0 | 3.8 | 3.76 | 64 | 998/1058 | |
3.00 | 4.1 | 3.98 | 53 | 960/1027 | |||
2.00 | 4.3 | 4.49 | 47 | 867/923 | |||
1.00 | 5.2 | 6.07 | 25 | 716/831 | |||
4% HCl + 2.0 M KCl | 4.00 | 12.0 | 3.2 | 3.47 | 70 | 901/1081 | |
3.00 | 3.3 | 3.92 | 62 | 968/1038 | |||
2.00 | 3.5 | 5.18 | 56.5 | 820/943 | |||
1.00 | 3.6 | 5.34 | 34 | 783/896 | |||
4% HCl + 3.0 M KCl | 4.00 | 12.0 | 3.0 | 3.56 | 72 | 916/1076 | |
3.00 | 3.1 | 3.92 | 67 | 951/1028 | |||
2.00 | 3.2 | 5.66 | 65.5 | 800/889 | |||
1.00 | 3.6 | 6.49 | 39 | 785/873 | |||
Underground Water | 4% HCl (control) | 4.00 | 12.0 | 2.7 | 2.96 | 45.5 | 1041/1082 |
3.00 | 3.1 | 3.50 | 38 | 942/1039 | |||
2.00 | 3.9 | 3.80 | 20.5 | 871/994 | |||
1.00 | 5.2 | 5.43 | 11.5 | 792/871 | |||
4% HCl + 1.0 M KCl | 4.00 | 12.0 | 2.5 | 3.27 | 55 | 1013/1104 | |
3.00 | 3.2 | 3.34 | 54 | 957/1063 | |||
2.00 | 4.0 | 4.34 | 42 | 878/1001 | |||
1.00 | 4.8 | 5.89 | 20 | 739/858 | |||
4% HCl + 2.0 M KCl | 4.00 | 12.0 | 3.5 | 3.28 | 63 | 975/1064 | |
3.00 | 3.4 | 3.61 | 59 | 926/1029 | |||
2.00 | 3.4 | 4.13 | 40 | 838/1023 | |||
1.00 | 4.0 | 5.65 | 36 | 792/869 | |||
4% HCl + 3.0 M KCl | 4.00 | 12.0 | 3.0 | 3.18 | 69 | 951/1050 | |
3.00 | 3.1 | 3.44 | 67 | 948/1101 | |||
2.00 | 3.1 | 3.71 | 50 | 934/1019 | |||
1.00 | 3.3 | 5.93 | 38 | 769/854 | |||