Table 1 Quantitative temperature errors of constructions (%).
From: Construction of three-dimensional temperature distribution using a network of ultrasonic transducers
Models | Without noise | With noise | ||
|---|---|---|---|---|
E m | E r | E m | E r | |
T1 (x, y) | 0.281 | 0.115 | 3.103 | 0.956 |
T2 (x, y) | 0.602 | 0.319 | 2.977 | 1.187 |
T3 (x, y) | 1.640 | 1.067 | 3.233 | 1.651 |
T4 (x, y) | 7.854 | 3.965 | 8.680 | 4.212 |