Table 2 Charge transfer resistance (Rct) and double layer capacitance (Cdl) values obtained by fitting the electrochemical impedance spectra.

From: Nanoscopic and Macro-Porous Carbon Nano-foam Electrodes with Improved Mass Transport for Vanadium Redox Flow Batteries

Electrode

Electrolyte

\({{R}}_{{\bf{ct}}\_{\boldsymbol{A}}}\) (Ω cm2)

\({{C}}_{{\bf{dl}}\_{\boldsymbol{A}}}\) (µF cm−2)

\({{R}}_{{\bf{ct}}\_{\boldsymbol{B}}}\) (Ω cm2)

\({{C}}_{{\bf{dl}}\_{\boldsymbol{B}}}\) (µF cm−2)

TC

Negative

0.31

5,827.30

17.60

37,778.80

Positive

0.49

8697.60

N/A

N/A

PF

Negative

2.84

27,471.60

120.00

209,148.00

Positive

1.14

17,067.00

N/A