Table 1 Metrics comparison of different high-performance Hall elements working at room temperature. (‘Gr’ stands for graphene).
From: Gate-tunable graphene-based Hall sensors on flexible substrates with increased sensitivity
Substrate | Si (V/AT) | Sv (V/VT) | Bmin (nT/\(\surd Hz\)) | Frequency (kHz) | Conditions | |
|---|---|---|---|---|---|---|
Rigid | 100 | 0.1 | 5000 | 3 | n/a | |
Rigid | 2750 | 2.2 | 58 | 1 | Vacuum | |
GaAs29 | Rigid | 1100 | n/a | 800 | 3 | n/a |
Exfoliated Gr-hBN9 | Rigid | 4100 | 2.16 | 50 | 3 | Vacuum |
CVD Gr30 | Rigid | 800 | n/a | 500 | 3 | Air |
CVD Gr15 | Rigid | 2093 | 0.35 | 100 | 3 | Air |
CVD Gr8 | Flexible | 75 | 0.093 | n/a | n/a | Air |
CVD Gr-hBN22 | Flexible | 2270 | 0.68 | n/a | n/a | Air |
Bismuth31 | Flexible | 2.3 | n/a | n/a | n/a | Air |
This work | Flexible | 1500 | 0.55 | 500 | 2 | Air |
This work (max) | Flexible | 2580 | 0.68 | 290 | 2 | Air |