Table 1 Minimum beam sizes at the target simulated with new nozzle design for the different combinations of beam energy and air gap length. The sizes were obtained with multiple beam source configurations. The right part of the table lists the source parametrisations used for the dose simulations.

From: Advancing proton minibeam radiation therapy: magnetically focussed proton minibeams at a clinical centre

Configuration

Minimum beam size at target

Source beam parametrisation

beam energy [MeV]

air gap [cm]

hFWHM [mm]

vFWHM [mm]

\({\sigma }_{x}\) [mm]

\({\sigma }_{y}\) [mm]

\({x}^{^{\prime} }\) [mrad]

\({y}^{^{\prime} }\) [mrad]

\({r}_{x{x}^{^{\prime} }}\)

\({r}_{y{y}^{^{\prime} }}\)

100

30

\(1.6{7}_{-0.19}^{+0.001}\)

\(1.6{5}_{-0.40}^{+0.001}\)

6.5

10.0

5.0

5.0

\(-1\)

\(-1\)

100

10

\(0.6{6}_{-0.11}^{+0.001}\)

\(0.6{8}_{-0.11}^{+0.001}\)

4.0

4.0

3.0

3.0

\(-1\)

\(-1\)

200

30

\(0.8{7}_{-0.14}^{+0.001}\)

\(0.8{5}_{-0.07}^{+0.001}\)

5.0

3.5

1.0

0.5

1

\(-1\)