T.able 1 Performance comparison of the proposed sensor and other optical fiber-based humidity sensors reported in literature.
Sensing Material | Optical fiber | Sensing method | Range (%RH) | Sensitivity (Resolution) | Response time | Application |
|---|---|---|---|---|---|---|
Gelatin11 | Tapered optical fiber | Interferometric | 9–94 | 0.016 dBm/%RH | 70 ms | |
TiO2/SnO212 | Long Period Grating | Long Period Grating | 40–95 | 221 pm/%RH | — | |
Silica/di-ureas32 | Fiber Bragg grating | Fiber Bragg grating | 5–95 | 22.2 pm/%RH | Civil Engineered Structure Monitoring | |
PMMA polymer33 | Fiber Bragg grating | Etched Polymer Optical Fiber | 30–90 | 33.6 pm/%RH | 7 min | |
Polyvinyl Alcohal35 | Long Period Grating | Long Period Grating | 33–97 | ~5680 pm/%RH | <1 min | Structural Health Monitoring |
Polyvinyl Alcohol43 | Tilted Fiber Bragg Grating | Tilted Fiber Bragg Grating | 20–98 | 14.95 dBm/%RH | — | |
Calcium Chloride34 | Air gap Long Period Grating | Air gap long period grating | 50–95 | 1350 pm/%RH | ||
SiO2 –Nanospheres36 | Long Period Grating | Long Period Grating | 20–50 50–80 | 63.33 pm/%RH 451.78 pm/%RH | 30 ms (rise) 153 ms (recovery) | |
[PDDA/Poly R-478] nanostructured30 | Tapered Fiber | Evanescent wave | 75–100 | 16 dBm/%RH | 300 ms | |
Polyethylene Oxide (PEO)31 | Buffer-striped 1060XP Fiber | Evanescent wave | 80–95 | 1 dB/%RH | 760 ms | Breath Monitoring |
No coating37 | Silica/polymer Microfiber | Knot Resonator | 17–98 | 8.8 pm/%RH (0.017%) | ||
[poly-glutamic acid/poly-lysine]39 | Hetro-core Fiber | Modal Interferometric | 50–92.9 | 0.0052 dB/%RH | 400 ms | Breath Monitoring |
Polyvinyl Alcohol14 | Photonic Crystal Fiber | Modal Interferometric | 20–95 | 40.9 pm/%RH | — | |
(P4VP·HCl/PVS)1015 | Thin Core Fiber | Modal Interferometric | 20–90 | 84.3 pm/%RH (0.78%) | 2 sec (rise) 10 sec (fall) | |
Chitosan38 | Polarization Maintaining Fiber | Sagnac Interferometer | 20–95 | 81 pm/%RH (2.04%) | ||
Ti3O5/SiO216 | Single Mode Fiber | Fabry-Perot Interferometer | 1.8–74.7 | 430 pm/%RH | 5 sec | |
Chitosan26 | Hollow-Core PCF | Fabry-Perot Interferometer | 20–95 | 130 pm/%RH | 380 ms | |
(PAH/PSS)1544 | Hollow-Core PCF | Fabry-Perot Interferometer | 5–90 | 0.08 dB/%RH (0.125%) | 2 sec (rise) 6 sec (fall) | |
Chitosan17 | Hollow-Core PCF | Fabry-Perot Interferometer | 35–95 | 280 pm/%RH (0.02%) | <60 sec | |
SnO225 | Twin Suspended Core Fiber | Fabry-Perot Interferometer | 20–90 | 0.14 rad/%RH | 370 ms (rise) 380 ms (recovery) | Breath Monitoring |
Chitosan (Present Study) | Suspended tri-core Fiber | Fabry-Perot Interferometer | 30–95 | 81.05 pm/%RH (0.5%) | 80 ms (rise) 70 ms (recovery) | Breath Monitoring |