Table 3 Predictive refraction errors of all formulas.

From: Development of a new intraocular lens power calculation method based on lens position estimated with optical coherence tomography

 

New formula

Barrett universal II

Haigis

SRK/T

Mean prediction error

−0.04

0.02

−0.06

−0.07

Standard deviation

0.36

0.40

0.44

0.47

Minimum

−0.99

−0.93

−1.32

−1.46

Maximum

0.94

1.12

1.57

1.60

Mean absolute error

0.29

0.31

0.35

0.36

Median absolute error

0.25

0.27

0.30**

0.27**

Percentage of errors within diopter range

±0.25D

49.9%

48.7%

42.1%

44.8%

±0.50D

84.3%

78.0%*

75.1%**

73.9%**

±0.75D

96.1%

93.2%

92.9%

87.8%*

±1.00D

100%

99.1%

97.9%

96.1%**

  1. Median absolute error and percentage of errors within diopter range in New formula were compared with other existing formula.
  2. *p < 0.05, **p < 0.01.