Table 2 Results summary for the ICON method.
From: Real-time Inference and Detection of Disruptive EEG Networks for Epileptic Seizures
Patient # | NS | TP | FP | L (s) | S (%) | D (s) | FP/h |
|---|---|---|---|---|---|---|---|
1 | 7 | 7 | 0 | 2.00 | 100.00 | −4.00 | 0.00 |
2 | 3 | 1 | 0 | 0.00 | 33.33 | −25.00 | 0.00 |
3 | 7 | 7 | 1 | 5.14 | 100.00 | −0.86 | 0.03 |
4 | 4 | 4 | 0 | 10.25 | 100.00 | 4.25 | 0.00 |
5 | 5 | 5 | 0 | 18.80 | 100.00 | 12.80 | 0.00 |
6 | 10 | 1 | 0 | 80.00 | 10.00 | 74.00 | 0.00 |
7 | 3 | 3 | 0 | 11.00 | 100.00 | 5.00 | 0.00 |
8 | 5 | 4 | 0 | 0.50 | 80.00 | −5.50 | 0.00 |
9 | 4 | 4 | 0 | 0.25 | 100.00 | −5.75 | 0.00 |
10 | 7 | 5 | 0 | 1.60 | 71.43 | −4.40 | 0.00 |
11 | 3 | 2 | 0 | 8.00 | 66.67 | 2.00 | 0.00 |
12 | 40 | 32 | 2 | 3.25 | 80.00 | −2.75 | 0.08 |
13 | 12 | 10 | 5 | 11.40 | 83.33 | 5.40 | 0.15 |
14 | 8 | 3 | 0 | 0.00 | 37.50 | −6.00 | 0.00 |
15 | 20 | 17 | 2 | 2.41 | 85.00 | −3.59 | 0.05 |
16 | 10 | 7 | 0 | 5.57 | 70.00 | −0.42 | 0.00 |
17 | 3 | 2 | 1 | 0.00 | 66.67 | −6.00 | 0.05 |
18 | 6 | 5 | 3 | 4.00 | 83.33 | −2.00 | 0.08 |
19 | 3 | 3 | 0 | 0.00 | 100.00 | −6.00 | 0.00 |
20 | 8 | 7 | 1 | 2.71 | 87.50 | −3.28 | 0.04 |
21 | 4 | 2 | 0 | 0.00 | 50.00 | −6.00 | 0.00 |
22 | 3 | 3 | 0 | 0.00 | 100.00 | −6.00 | 0.00 |
23 | 7 | 7 | 1 | 1.71 | 100.00 | −4.28 | 0.04 |
24 | 16 | 15 | 0 | 1.20 | 93.75 | −4.80 | 0.00 |
Total (24 patients) | 198 | 156 | 16 | ||||
Mean | 4.44 | −1.68 | |||||
Sensitivity | 78.79% | ||||||
FP/h | 0.0186 |