Table 2 Estimates for the LMER model presented in Eq. (1) for predicting burn depth severity based on HSB measurements from an unmodified DSLR camera.

From: Early visualization of skin burn severity using a topically applied dye-loaded liquid bandage

LMER Eq. 1

Fixed Effect

Estimate of Coefficient

p-value

B0 (Intercept)

0.26

0.12

B1 (Day)

−219.30

0.034*

B2 (Hue)

−5.80E-04

9.38E-06***

B3 (Saturation)

6.56E-04

0.046*

B4 (Brightness)

−1.28E-04

0.89

  1. Significance codes: <0.001***, <0.01**, and <0.05*.