Table 2 SPCCT diagnostic performance for the detection of peritoneal metastases (TP: true-positive; FP: false-positive; TN: true-negative; FN: false-negative; Se: sensitivity; Sp: specificity; Acc: accuracy).

From: Spectral photon-counting CT imaging of colorectal peritoneal metastases: initial experience in rats

#

Regions

Protocols A + B

Protocol A

Protocol B

TP

FP

TN

FN

Se (%)

Sp (%)

Acc (%)

TP

FP

TN

FN

Se (%)

Sp (%)

Acc (%)

TP

FP

TN

FN

Se (%)

Sp (%)

Acc (%)

0

Central

11

0

2

3

79

100

81

5

0

1

2

71

100

75

6

0

1

1

86

100

88

1

RUQ

3

0

7

6

33

100

63

1

0

4

3

25

100

63

2

0

3

3

40

100

63

2

Epigastrium

8

0

3

5

62

100

69

4

0

2

2

67

100

75

4

0

1

3

57

100

63

3

LUQ

6

0

6

4

60

100

75

3

0

3

2

60

100

75

3

0

3

2

60

100

75

4

L Flank

2

0

10

4

33

100

75

1

0

5

2

33

100

75

1

0

5

2

33

100

75

5

LLQ

6

0

8

2

75

100

88

3

0

5

0

100

100

100

3

0

3

2

60

100

75

6

Pelvis

8

0

7

1

89

100

94

5

0

3

0

100

100

100

3

0

4

1

75

100

88

7

RLQ

9

0

6

1

90

100

94

5

0

3

0

100

100

100

4

0

3

1

80

100

88

8

R Flank

11

0

4

1

92

100

94

5

0

3

0

100

100

100

6

0

1

1

86

100

88

9

Proximal Jejunum

6

0

4

6

50

100

63

2

0

3

3

40

100

63

4

0

1

3

57

100

63

10

Distal jejunum

8

0

5

3

73

100

81

3

0

2

3

50

100

63

5

0

3

0

100

100

100

11

Proximal ileum

8

0

5

3

73

100

81

3

0

2

3

50

100

63

5

0

3

0

100

100

100

12

Distal ileum

7

0

6

3

70

100

81

2

0

4

2

50

100

75

5

0

2

1

83

100

88

Total

93

0

73

42

69

100

80

42

0

40

22

66

100

79

51

0

33

20

72

100

81