Table 1 Sensitivity, specificity and area under the receiver operating characteristic curve (AUC) for 3D OCT and intraoral digital radiography (IDR) for the detection of enamel demineralization, enamel caries, and dentin caries.

From: 3D imaging of proximal caries in posterior teeth using optical coherence tomography

Examiner #

Method

Sensitivity

Specificity

AUC

0 versus 1–3

0–1 versus 2–3

0–2 versus 3

0 versus 1–3

0–1 versus 2–3

0–2 versus 3

1

3D OCT

0.85

0.93

0.88

0.83

0.91

0.97

0.95

IDR

0.54

0.55

0.47

0.83

0.91

0.94

0.75

2

3D OCT

0.90

0.90

0.88

0.42

0.73

0.97

0.96

IDR

0.59

0.52

0.29

0.83

0.77

0.88

0.69

3

3D OCT

0.92

0.97

0.82

0.83

0.82

0.97

0.95

IDR

0.62

0.34

0.29

0.50

0.91

0.97

0.70

4

3D OCT

0.97

0.90

0.94

0.55

0.67

0.97

0.95

IDR

0.69

0.45

0.29

0.67

0.77

0.88

0.71

5

3D OCT

0.95

0.83

1.00

0.58

0.82

0.94

0.97

IDR

0.82

0.76

0.65

0.33

0.86

0.85

0.78

6

3D OCT

0.85

1.00

0.94

0.92

0.95

1.00

0.99

IDR

0.82

0.76

0.47

0.58

0.95

0.94

0.78

7

3D OCT

0.87

0.90

0.88

0.83

0.91

0.97

0.97

IDR

0.69

0.76

0.59

0.92

0.91

0.82

0.73

8

3D OCT

0.95

0.97

0.94

0.83

0.91

0.97

0.94

IDR

0.90

0.76

0.65

0.83

0.77

0.91

0.82

9

3D OCT

0.97

0.69

0.47

0.58

0.77

0.97

0.89

IDR

0.67

0.38

0.18

0.67

1.00

0.97

0.74

10

3D OCT

0.82

0.86

0.82

0.83

0.95

0.97

0.91

IDR

0.74

0.59

0.41

0.50

0.91

0.97

0.72

11

3D OCT

0.90

1.00

0.88

0.75

0.95

0.97

0.96

IDR

0.92

0.72

0.71

0.67

0.95

0.88

0.84

12

3D OCT

0.87

0.79

0.76

0.75

0.86

1.00

0.95

IDR

0.87

0.59

0.41

0.33

0.91

0.91

0.77

13

3D OCT

0.74

0.62

0.82

0.75

0.95

0.94

0.92

IDR

0.59

0.45

0.41

0.42

0.73

0.91

0.68

Mean (SD)

3D OCT

0.89 (0.064)

0.87 (0.11)

0.85 (0.13)

0.73 (0.14)

0.86 (0.092)

0.97 (0.016)

0.94 (0.026)

IDR

0.73 (0.12)

0.59 (0.15)

0.45 (0.16)

0.62 (0.19)

0.87 (0.082)

0.91 (0.045)

0.75 (0.048)

P value, significance

p = 0.015, S

p = 0.0013, S

p = 0.000042, S

p = 0.18, NS

p = 0.90, NS

p = 0.0019, S

p = 0.000014, S

  1. S: Significant difference between the values for SS-OCT and intraoral digital radiography.
  2. NS: No significant difference between the values for SS-OCT and intraoral digital radiography.