Table 2 Results of visual field testing in each IOL group.

From: Influence of implantations of extended depth-of-focus on standard automated perimetry

 

Multi group

EDOF group

Mono group

P value

MD (dB)

 − 1.82 ± 1.24

 − 0.80 ± 1.13

 − 0.39 ± 0.96

 < 0.001*

(− 4.63 to 0.25)

(− 2.95 to 1.32)

(− 2.15 to 1.35)

PSD (dB)

1.34 ± 0.67

1.25 ± 0.30

1.23 ± 0.48

0.45**

(0.8 to 4.45)

(0.85 to 2.29)

(0.8 to 3.16)

Foveal sensitivity (dB)

33.28 ± 1.87

34.21 ± 2.16

34.6 ± 1.78

0.045**

(29 to 37)

(29 to 37)

(31 to 38)

MS (dB)

30.37 ± 1.24

31.49 ± 1.16

31.66 ± 0.96

 < 0.001*

(27.10 to 32.33)

(29.51 to 34.26)

(29.94 to 33.05)

  1. Mean ± SD (range).
  2. EDOF extended depth-of-focus, Multi multifocal, Mono monofocal, MD mean deviation, PSD pattern standard deviation, MS mean sensitivity.
  3. *ANOVA; **Kruskal–Wallis test.