Table 2 Sensitivity, median dice similarity coefficient (DSC), precision, F1 score, and average false positive (FPs)/scan for five-fold-cross-validation results of the different DLMs as well as results for DLM-Ens in relation to aneurysm volume.
DLM-Orig | DLM-Vess | DLM-LDim | DLM-Ens | DLM-Ens > 30 mm3 | DLM-Ens > 50 mm3 | |
|---|---|---|---|---|---|---|
Sensitivity (detected/missed) | 76% (60/19) | 76% (60/19) | 70% (55/24) | 72% (57/22) | 84% (54/10) | 91% (50/5) |
DSC (median) | 0.54 | 0.58 | 0.69 | 0.74 | 0.79 | 0.81 |
Precision (detected/FP) | 30% (60/142) | 31% (60/136) | 53% (55/48) | 80% (57/14) | 88% (54/7) | 94% (50/3) |
F1 score | 0.43 | 0.44 | 0.59 | 0.76 | 0.86 | 0.93 |
FPs/scan (FP/number of scans) | 2.10 (142/68) | 2.00 (136/68) | 0.71 (48/68) | 0.21 (14/68) | 0.10 (7/68) | 0.05 (3/68) |