Table 4 Diagnostic performance of optical diagnosis of colorectal neoplastic polyps by three modalities for the non-expert group.

From: The value of three narrow-band imaging model in the diagnosis of small colorectal polyps

Modality

NBI (95% CI)

NBIME (95% CI )

AA-NBIME (95% CI)

\(P_{{NBI vs AA{ - }NBIME}}\)

\(P_{NBI vs NBIME}\)

\(P_{{NBIME vs AA{ - }NBIME}}\)

Sensitivity

81.8% (75.9–87.7)

85.5% (80.1–90.8)

91.5% (87.3–95.8)

 < 0.001

0.014

0.033

Specificity

77.1% (68.7–85.5)

82.3% (74.7–89.9)

85.4% (78.4–92.5)

0.157

0.025

0.590

Accuracy

80.1% (74.8–84.5)

84.3% (79.4–88.2)

89.3% (84.9–92.5)

0.005

0.253

0.121

PPV

86.0% (80.6–91.4)

89.2% (84.4–94.1)

91.5% (87.3–95.8)

0.083

0.012

0.469

NPV

71.2% (62.4–79.9)

76.7% (68.5–84.9)

85.4% (78.4–92.5)

 < 0.001

0.004

0.029

  1. PPV positive predictive value, NPV negative predictive value.