Table 4 Parameters for the energy detector for Bp-20 Hz, Plus.
Lower frequency bound (Hz) | 15 |
Upper frequency bound (Hz) | 30 |
Thresholds | 0.5, 1, 2, 3, 4, 5, 8, 16, 32, 64 |
Minimum time over threshold (s) | 0.5 |
Maximum time over threshold (s) | 2.5 |
Minimum time before next detection (s) | 1 |
FFT time resolution (s) | 1.024 |
FFT frequency resolution (Hz) | 0.98 |
Noise normalisation type | Average subtraction |
Average subtraction: Update constant | 0.01 |