Table 2 Experimental considerations, materials, and average degradation rate of W, Ni0,8Cr0,2 and stainless steel.

From: Materials degradation in non-thermal plasma generators by corona discharge

Material

D (µm)

Number assays

\(\Delta \) V (kV)

Exposure time, tf (h)

Corona power reduction (%)

Final state

Final current, I (µA/cm)

Qf (C/cm)

ea (µg/C)

Stainless steel 302

50

12

4.75

50

72.7

Rupture

15

4

29

Ni0.8Cr0.2

50

8

4.75

95

48

Rupture

32.5

11.1

7.6

Tungsten

50

18

4.5–4.75

1630

56.5

Stopped

50

300.42

0.92

25

8

4–4.3

450

40.3

Stopped

27.5

44.5

3.7

100

10

4.9–5.2

600

65.2

Stopped

40

86.4

5.3