Table 1 Comparison of the healthy condition outputs with in vivo reference data given as a mean with range.

From: Understanding and recognition of the right ventricular function and dysfunction via a numerical study

Parameters

Units

Model

Reference

CO

[L/min]

6.2

6.5 (3.6–9.4)21

Total vascular resistance

SVR

\(\left[ {{\text{mmHg}} \cdot {\text{s/mL}}} \right]\)

0.89

0.8 (0.5–1.1)21

PVR

\(\left[ {{\text{mmHg}} \cdot {\text{s/mL}}} \right]\)

0.06

0.06 (0.02–0.09)21

Volume

\(LV_{max}\)

[mL]

144

150 (119–181)36

\(RV_{max}\)

[mL]

153

173 (134–212)36

\(LA_{max}\)

[mL]

111

97 (70–124)36

\(RA_{max}\)

[mL]

107

101 (37–177)37

\(LV_{min}\)

[mL]

62

47 (32–62)36

\(RV_{min}\)

[mL]

71

69 (47–91)36

\(LA_{min}\)

[mL]

72

44 (31–57)36

\(RA_{min}\)

[mL]

66

50 (15–92)37

Pressure

SBP

[mmHg]

120

125 (118–132)38

DBP

[mmHg]

66

73 (68–78)38

PuA (systolic)

[mmHg]

18.3

22.5 (21.5–23.5)39

PuA (mean)

[mmHg]

13.5

15.5 (12.9–18.1)39

E/A ratio

Mitral

[–]

4.6

0.6–2.640

Tricuspid

[–]

1.1

0.8–2.340