Table 3 Algorithm precision results.
From: Automated detection of cerebral microbleeds on T2*-weighted MRI
True positives | False positives | Precision | Average FP/scan | |
|---|---|---|---|---|
Microbleed positive | ||||
SWI | 50 | 426 | 0.11 | 9.7 |
GRE | 56 | 752 | 0.07 | 17.1 |
Microbleed negative | ||||
SWI | – | 249 | – | 7.32 |
GRE | – | 544 | – | 15.4 |
Follow up | ||||
SWI | 10 | 160 | 0.06 | 3.64 |