Table 4 Power loss distribution of the proposed topology.

From: Experimental validation of new self-voltage balanced 9L-ANPC inverter for photovoltaic applications

Power loss of

Output power (W)

100Ω + 50 mH

50Ω + 100 mH

10Ω + 100 mH

Psw

Pc

Ploss

Psw

Pc

Ploss

Psw

Pc

Ploss

Switch S1

0.6075

0.1219

0.7294

2.8914

0.1030

2.9944

1.2983

0.0185

1.3168

Switch B1

1.4077

0.0014

1.4091

2.6635

0.0035

2.667

0.6502

0.0003

0.6505

Switch S1′

1.3847

0.1117

1.4964

2.6001

0.1592

2.7593

1.1675

0.0389

1.2064

Switch Sx

1.1172

0.2316

1.3488

2.1838

0.2316

2.4154

1.2343

0.1915

1.4258

Switch S2

2.3160

0.0407

2.3560

4.1637

0.0538

4.2175

1.5402

0.0883

1.6285

Switch S2′

2.2384

0.0388

2.2772

4.1613

0.0414

4.2027

1.5321

0.0736

1.6057

Switch B2

0.5490

0.3152

0.8642

1.2362

0.3297

1.5659

1.4434

0.3359

1.7793

Switch S3

0.4493

0.1427

0.592

0.9414

0.1446

1.086

0.7699

0.1070

0.8769

Switch S3′

0.4481

0.1545

0.6026

0.9356

0.1546

1.0902

0.7549

0.1230

0.8779

Capacitor C1/C2

0.6908

1.7347

0.2981

Capacitor Ca/Cb

3.2147

8.0664

0.6308

Didoes of switch B1

3.0782

5.7540

3.2717

Didoes of switch B2

1.2792

2.8041

1.4694

Total losses (W)

20.9518

48.9956

15.5274

Efficiency (%)

97.7

95.67

94.93