Table 1 Reactivity classification of the CCP samples.

From: Distinct SARS-CoV-2 antibody reactivity patterns in coronavirus convalescent plasma revealed by a coronavirus antigen microarray

CCP #

VITROS CoV2T S/C ratio

VITROS CoV2T interpretation

RVPN NT50

RVPNT interpretation

COVAM RF probability

COVAM RF interpretation

Concordance

CoV2T vs RVPNT

CoV2T vs COVAM rf

RVPNT vs COVAM rf

1

0.01

Non-Reactive

 < 40

Non-reactive

0.796

Reactive

1

0

0

2

0.02

Non-Reactive

 < 40

Non-reactive

0.21

Non-reactive

1

1

1

3

0.31

Non-Reactive

 < 40

Non-reactive

0.38

Non-reactive

1

1

1

4

1.39

Reactive

279.5

Reactive

0.996

Reactive

1

1

1

5

1.45

Reactive

145.5

Reactive

0.402

Non-reactive

1

0

0

6

2.14

Reactive

302.4

Reactive

0.996

Reactive

1

1

1

7

2.77

Reactive

4171

Reactive

1

Reactive

1

1

1

8

4.24

Reactive

 < 40

Non-reactive

0.86

Reactive

0

1

0

9

4.48

Reactive

 < 40

Non-reactive

0.836

Reactive

0

1

0

10

5.21

Reactive

617

Reactive

1

Reactive

1

1

1

11

5.36

Reactive

132.2

Reactive

0.402

Non-reactive

1

0

0

12

5.62

Reactive

3583

Reactive

1

Reactive

1

1

1

13

6.22

Reactive

97.58

Reactive

0.868

Reactive

1

1

1

14

7.54

Reactive

 < 40

Non-reactive

0.848

Reactive

0

1

0

15

9.37

Reactive

 < 40

Non-reactive

0.372

Non-reactive

0

0

1

16

9.45

Reactive

 < 40

Non-reactive

0.966

Reactive

0

1

0

17

9.8

Reactive

132.8

Reactive

0.984

Reactive

1

1

1

18

10.3

Reactive

 < 40

Non-reactive

0.602

Reactive

0

1

0

19

11

Reactive

6910

Reactive

1

Reactive

1

1

1

20

12.4

Reactive

 < 40

Non-reactive

0.95

Reactive

0

1

0

21–99

12.9–436

Reactive

 > 131

Reactive

0.8—1

Reactive

79

79

79

      

% concordance

93%

96%

91%

  1. CCP samples were analyzed by the COVAM array as well as the VITROS CoV2T chemiluminescence and RVPNT assays. The results from the two computational methods as well as VITROS and RVPNT assays show high concordance, especially for the high titer samples. A higher concordance (96%) was observed between the VITROS assay and COVAM array.