Table 3 Sample size calculation.

From: Impact of fully automated assessment on interstudy reproducibility of biventricular volumes and function in cardiac magnetic resonance imaging

Detected differences in volumetric indices

Observer A

Observer B

Automated

SD

Sample size

SD

Sample Size

SD

Sample Size

Left ventricle

10 g Mass

5.35

5

15.78

40

7.55

9

10 ml EDV

6.51

7

23.76

89

14.09

32

10 ml ESV

8.01

11

14.69

34

9.94

16

10 ml SV

6.39

7

15.21

37

9.29

14

5% EF

2.98

6

5.40

19

3.01

6

Right ventricle

10 ml RV EDV

6.72

8

17.70

50

22.12

77

10 ml RV ESV

5.97

6

16.29

42

13.07

27

10 ml RV SV

7.49

9

21.56

73

19.56

61

5% RV EF

3.51

8

10.50

70

7.12

32

  1. Sample size calculation for repeated measurements of left and right ventricular volumes for the detection of changes amounting to 10 g mass, 10 ml volumes and 5% EF respectively.