Table 2 Calculation cases with the same opening mode under different discharges.
Case no | Discharge (m3/s) | Opening mode of units | Discharge of each unit (m3/s) | Proportion of suitable area (%) |
|---|---|---|---|---|
1 | 5590 | Open 14 units, #8–21 | 243.2 | 95.1 |
2 | 6000 | Open 14 units, #8–21 | 252 | 95.5 |
3 | 7000 | Open 14 units, #8–21 | 294 | 97.1 |
4 | 8000 | Open 14 units, #8–21 | 336 | 98.0 |
5 | 9000 | Open 14 units, #8–21 | 378 | 97.4 |
6 | 10,000 | Open 14 units, #8–21 | 420 | 94.6 |
7 | 11,000 | Open 14 units, #8–21 | 462 | 96.1 |
8 | 12,000 | Open 14 units, #8–21 | 504 | 70.7 |
9 | 13,000 | Open 14 units, #8–21 | 546 | 66.9 |
10 | 14,000 | Open 14 units, #8–21 | 588 | 65.2 |
11 | 15,000 | Open 14 units, #8–21 | 630 | 54.6 |
11 | 16,000 | Open 14 units, #8–21 | 672 | 40.7 |
12 | 17,000 | Open 14 units, #8–21 | 714 | 26.3 |
13 | 17,930 | Open 14 units, #8–21 | 753 | 20.2 |
14 | > 17,930 | Open 14 units, #8–21 | 825 | 6.0 |