Table 4 Differences in median (interquartile range) gap and step-off measurements between more-experienced and less-experienced observers.

From: The accuracy of gap and step-off measurements in acetabular fracture treatment

 

More-experienced observers

Less-experienced observers

P-value

Preoperative gap

Radiographs

6.3 (1.9–10.7) mm

7.7 (1.9–14.2) mm

0.003

CT scans

17.5 (10.5–28.9) mm

19.5 (11.3–26.0) mm

0.080

Preoperative step-off

Radiographs

6.3 (0.6–18.1) mm

3.7 (0–8.7) mm

0.000

CT scans

9.0 (3.5–13.9) mm

9.5 (5.3–15.0) mm

0.024

Postoperative gap

Radiographs

0.0 (0.0–2.3) mm

2.9 (2.9–4.4) mm

0.000

CT scans

3.5 (2.1–5.5) mm

8.0 (6.0–10.0) mm

0.000

Postoperative step-off

Radiographs

0.0 (0.0–0.0) mm

0.0 (0.0–0.0) mm

0.823

CT scans

1.0 (0.0–2.4) mm

4.0 (1.3–5.8) mm

0.000

  1. P ≤ 0.05 was considered statistically significant.